When a tile shower fails, the cause is usually underneath the tile. Poor waterproofing workmanship, the wrong materials, or both.
The first signs usually show up outside the shower. Stained or swollen baseboards. Soft drywall along the floor next to the shower. Water on the bathroom floor, or a stain on the ceiling below when the bathroom is upstairs. Our post on the warning signs your shower is leaking behind the wall covers what to look for.
In the showers we’ve repaired around Greenville, Greer, Taylors, Simpsonville and the surrounding Upstate, a lot of that damage traces back to the same installation mistakes. Here’s what we find, how it should have been built, and how we decide whether a shower can be repaired or needs to be rebuilt.
Jump to: How we inspect a leaking shower · Repair or rebuild?
How does waterproofing work in a tile shower?
Tile and grout don’t make a shower waterproof. Cement-based grout and mortar let water through, and that’s expected. What protects the walls, framing and subfloor is the waterproofing behind and under the tile.
There are two common ways to do it. A traditional shower pan uses a waterproof liner under a mortar bed. Newer systems use a waterproof membrane directly behind the tile. Both work when they’re installed correctly, and both fail when steps get skipped.
The finished tile can look perfect either way. It tells you nothing about what’s underneath.
How should a shower pan liner be installed at the drain?
In a traditional shower, water that gets through the grout and mortar is meant to run along the liner and out through small weep holes in the drain. When the liner is installed wrong, that water goes somewhere else.
When the shower floor cracks, or water comes through the floor or the ceiling below, we usually find one of three things. The drain was installed wrong, the waterproofing was missing or installed wrong, or, on rare occasions, there’s a plumbing leak.
A clamping drain is built in layers. The drain base sits at the bottom, a clamping ring bolts down on top of it, and the drain barrel and strainer thread in above that. The liner is supposed to be sandwiched between the base and the clamping ring, so the ring squeezes it tight all the way around.
The issue we come across most is the liner not being sandwiched at all. Usually the whole drain assembly is set on top of the liner, so the liner runs underneath the drain base instead of being clamped. The next most common is the wrong drain to begin with: a non-clamping drain set on top of the liner, with nothing to hold the liner to it. That’s the wrong material chosen before the shower was ever built. We also find only part of the liner caught inside the clamp.

Oatey and Noble are two companies that manufacture shower pan liners, and both publish installation instructions. At the drain they call for:
- A sloped bed under the liner. Oatey calls for a mortar bed sloped 1/4 inch per foot toward the drain. Noble says it has to slope toward the drain’s weep holes with no low spots where water can pond.
- A clamping drain, sealed and tightened down. The liner is sealed to the drain body and the clamping ring is tightened onto it. Noble also says to check the drain for warping before it goes in, and to replace one that’s warped.
- Weep holes that can drain. Noble requires drains with weep holes, and the bed has to slope to them.

What happens when a shower pan liner isn’t sloped correctly?
A traditional shower pan liner should go over a properly sloped surface, not directly on a flat subfloor. Water that gets through the tile and mortar reaches the liner and follows the slope to the drain’s weep holes.
Without that slope, water stays trapped in the mortar bed. Over time that trapped moisture can lead to constant dampness, odors, mineral deposits and discoloration. Blocked weep holes cause the same problems, even when the liner itself hasn’t leaked.
A wet mortar bed doesn’t automatically mean water is getting into the framing. Poor drainage does keep the shower floor saturated longer than it should be. That’s why a traditional shower pan needs both a pre-slope under the liner and weep holes that work.
How should a shower pan liner go over the curb?
When we find water damage on the outside of the curb, along the baseboard and drywall, it usually means one of two things. The joint where the curb meets the wall wasn’t waterproofed correctly, or nails were run through the liner on the inside of the curb. The second one is common.
The liner is supposed to run continuously over the curb. Every unsealed cut or exposed fastener is another way for water to get into the structure. The curb-to-wall connection matters most, because water reaches it during normal shower use.

At the curb, Oatey’s and Noble’s instructions call for:
- Fasteners only where they belong. On the walls, Oatey says to staple only in the top 1/2 inch of the liner, and Noble says within the top 1 inch. On the curb, both fasten over the top and on the outside face. Neither calls for fasteners anywhere else.
- Liner high enough. Noble calls for the liner to run at least 3 inches above the finished curb. Oatey has you mark 5 inches up from the curb.
- Corners folded, not cut, with dam corners at the curb. Both fold the inside corners. Oatey sets a preformed dam corner at every spot where the curb meets the wall, and Noble recommends them even where they aren’t required.




How do Schluter and other sheet membrane showers fail?
Sheet membrane systems like Schluter KERDI put a waterproof layer directly behind the tile. Installed to the manufacturer’s specs, they do the job. The membrane is only as good as how it’s put together, and when one fails we usually find one of these things:
- Seams that weren’t joined correctly. Schluter’s data sheet calls for a 2-inch overlap at KERDI seams.
- Mortar that was too thick, or had dried, at the transitions.
- Improper layering that lets water pour in.
- Poor membrane bonding or incomplete mortar coverage.
- Corners and transitions that weren’t waterproofed correctly.
- Plumbing penetrations that were never sealed.
- Bad connections between the walls, the shower pan and the drain.
A wall can be covered almost edge to edge and still leak at one bad seam or transition.
Is KERDI over drywall a good choice for a shower?
Schluter approves drywall as a backing for KERDI. Built to their instructions, it isn’t a failure on day one, and it isn’t our preferred way to build a shower.
KERDI isn’t a complete vapor barrier. Schluter rates it at 0.90 perms, tested to ASTM E96, which means some water vapor moves through it. Drywall is gypsum, and moisture breaks gypsum down over time. A wall that was structurally sound on day one may not be as sound six years later.
That matters most when the shower needs a repair. Taking tile off damages the membrane behind it. With drywall that has softened, the board can crumble or pull apart when it’s opened, and there’s nothing sound left to tie new waterproofing into. A repair that should have been a section of one wall can turn into a much bigger job, or become impossible.
Purple board is moisture resistant, not waterproof. It’s the best option if someone goes the drywall route, but it still degrades with water or too much humidity, and it doesn’t hold up over time the way cement board or foam board does.

Why do we prefer GoBoard for shower walls?
GoBoard is a waterproof foam backer board, and it’s what we use on our shower walls on every job. The board itself is waterproof. Its seams, fasteners and penetrations still have to be sealed to make the whole wall waterproof.
We like it because it’s lightweight, easy to work with, and made for wet areas. The bigger reason is what happens years later. If a section gets damaged, we can usually cut it out cleanly, put in new board, and tie the waterproofing back in without tearing out the rest of the shower. Our guide to the best backer board for a shower compares it with the other options.
Do I need to waterproof cement board in a shower?
Yes. With standard cement board, like Durock or HardieBacker, best practice is to waterproof the whole panel, not just the seams. The exception is a board made specifically to be waterproof, like PermaBase WP, where the seams and fasteners are what get waterproofed.
Over backer board, the waterproofing is typically a roll-on, but a fabric membrane is acceptable as well. When backer board and a roll-on fail, it’s usually all of it: missed coverage, too few coats or not enough thickness, the seams, the corners, gaps around plumbing penetrations, and the transition to the pan. A roll-on isn’t paint. It has to go on at the manufacturer’s required coverage and thickness, with the right prep and cure time. The seams have to be taped, mudded and sealed.
There are instances when something other than GoBoard is necessary, or a customer wants something specific. Cement board is a solid choice for a shower when it’s waterproofed correctly.

Can you mix different shower waterproofing systems?
Not every product is made to work with every other. Pan liners, roll-on membranes, sheet membranes and foam boards each have their own installation requirements. Problems start when materials get combined without a plan for how the whole shower handles water. A drain made for one system paired with a pan built for another is a common example. Each product can be good on its own and the shower can still fail.
How do you waterproof a shower niche or bench?
When a niche, bench or corner fails, it comes down to improper installation of the waterproofing. Each one adds corners and seams, and every one of them has to be tied into the waterproofing.
Why is a flood test so important?
Most of the failures we find are around the pan, where the walls meet the pan and where the curb meets the pan. That’s also where most of the waterproofing happens, which is why a flood test matters so much.
For a flood test, the drain is plugged below the waterproofing connection and the pan is filled with water before any tile goes down. Oatey’s instructions say to fill it to the height of the curb and let it sit at least two hours. It passes when the water level holds, the area around the shower stays dry, and nothing shows on the ceiling below if the bathroom is upstairs.
We run ours for 24 hours, after the materials have cured. The pan takes the most water, so it’s the right place to test, and our difference is how long we let it sit. The drain shown earlier was never flood tested. A flood test would have caught it.
How do we inspect a leaking shower?
We start with a free visual inspection and estimate. We look at the shower and the bathroom around it for cracked grout, failed silicone, loose tile, swollen baseboards, soft drywall and damaged flooring. When we can get underneath, we check around the drain, the subfloor and the framing.
Most of a shower’s waterproofing is hidden behind the tile, so a visual inspection can’t always tell how far the damage goes.
When we need more information, we offer a moisture inspection with a written report, starting at $325. The fee is credited toward the repair once you approve and sign our estimate. We use a FLIR MR277 moisture meter and take both pin and pinless readings. Its built-in thermal camera shows temperature variations on the surface of the tile or walls, which can point to moisture behind them and guide us to where moisture readings should be taken. We take baseline readings away from the shower and inside it first, then compare the suspect areas against them. What matters is the difference between readings, not one number on its own. The report documents what we tested, the readings, photos, and what we think they mean.
A flood test of the shower pan is part of every moisture inspection, and we watch for readings that change outside or under the shower. The exceptions are when it can’t be done, such as when part of the shower has already been torn out, or when it’s already clear the pan doesn’t hold water.
When can a leaking shower be repaired, and when does it need to be rebuilt?
Not every leaking shower needs to be torn out. What decides it isn’t how much damage you can see. It’s where the water is coming from, the condition of what’s underneath, and whether the waterproofing can be restored properly.
A repair is often possible when:
- The grout or silicone has failed and the waterproofing behind it is intact.
- The leak is a plumbing connection we can reach without removing tile.
- A few tiles are loose or damaged and the backing and waterproofing underneath are sound or can be restored.
- The waterproofing damage is contained, and new waterproofing can be tied into the existing system.
A rebuild is usually the better call when:
- The pan liner isn’t connected to the drain, has been punctured, or doesn’t go over the curb.
- Water has rotted the subfloor, framing or backing.
- The walls, corners, curb and pan all have problems, so fixing one spot leaves the others behind.
- The backing has deteriorated and there’s nothing sound to tie new waterproofing into.
A failed pan doesn’t always mean every wall comes down. Rebuilding the pan does mean removing enough tile and wall to restore the waterproofing where the walls and curb meet the floor.
When tile comes out for a repair, the waterproofing behind it damages easily, so it gets repaired or replaced. We repair when we can, because it saves you money. We never offer a repair when it would leave a compromised shower. More on how we handle it on our shower tile repair page.
Can you fix a leaking shower with new grout or sealer?
Sometimes new grout or silicone is all a shower needs, when the problem is surface maintenance. Grout, sealer and silicone can’t fix a failed waterproofing membrane or a pan liner that was installed wrong. If the water is getting out at the drain, the liner or a corner, sealing the tile surface only hides it while the damage keeps going.
Should you stop using a shower that’s leaking?
Yes. If you see swollen baseboards, soft drywall, water on the floor or a stain on the ceiling below, stop using the shower until the source is found. Every shower adds more water to the framing and subfloor. The cause might be a plumbing connection, a shower door or the waterproofing itself, and finding it comes before deciding on a repair.
Who should build and waterproof your shower?
Setting tile and building a waterproof shower are different skills, and a tile installer isn’t always capable of building and waterproofing a shower. A shower can have straight tile and clean grout lines and still be built wrong underneath.
Shower repairs, new showers and bathroom remodels throughout the Greenville, South Carolina area are what we specialize in, so waterproofing and repair are what we do. Shortcuts are wrong cuts.
If you’re seeing damage around your shower or planning a new one, call (864) 747-9325 for a free inspection and estimate anywhere in our service area.
Frequently Asked Questions
How long should a shower pan be flood tested?
Oatey’s instructions call for at least two hours with the pan filled to the height of the curb. We run ours for 24 hours before any tile goes down.
Is shower grout waterproof?
No. Cement-based grout lets water through, even when it’s sealed. The waterproofing behind and under the tile is what protects the structure.
Do I need to waterproof cement board in a shower?
Yes. Best practice with standard cement board is to waterproof the whole panel, not just the seams. A board made specifically to be waterproof only needs its seams and fasteners done.
Can Schluter KERDI go over drywall?
Schluter approves it. Drywall still breaks down with moisture over time, which can make future repairs difficult or impossible, so we prefer a foam or cement backer board.
Is purple drywall waterproof?
No. It’s moisture resistant. It’s the best drywall option for a shower, but it still degrades with water or high humidity.
Can you fix a leaking shower drain without removing the tile floor?
It depends on the source. A plumbing connection can sometimes be fixed from underneath. If the pan liner or its connection at the drain has failed, part or all of the shower floor usually has to come out.
Is it cheaper to repair a leaking shower or replace it?
A repair costs less when the waterproofing can be restored properly. When the pan or waterproofing has failed in several places, repeated repairs can cost more over time without fixing the cause.
Ready to start your tile project?
Get a free, no-pressure estimate. Tell us what you have in mind and we’ll handle the rest, the right way.